  • Heart rate recovery and heart rate variability are unchanged in patients with coronary artery disease following 12 weeks of high-intensity interval and moderate-intensity endurance exercise training.

    PubMed

    Currie, Katharine D; Rosen, Lee M; Millar, Philip J; McKelvie, Robert S; MacDonald, Maureen J

    2013-06-01

    Decreased heart rate variability and attenuated heart rate recovery following exercise are associated with an increased risk of mortality in cardiac patients. This study investigated the effects of 12 weeks of moderate-intensity endurance exercise (END) and a novel low-volume high-intensity interval exercise protocol (HIT) on measures of heart rate recovery and heart rate variability in patients with coronary artery disease (CAD). Fourteen males with CAD participated in 12 weeks of END or HIT training, each consisting of 2 supervised exercise sessions per week. END consisted of 30-50 min of continuous cycling at 60% peak power output (PPO). HIT involved ten 1-min intervals at 88% PPO separated by 1-min intervals at 10% PPO. Heart rate recovery at 1 min and 2 min was measured before and after training (pre- and post-training, respectively) using a submaximal exercise bout. Resting time and spectral and nonlinear domain measures of heart rate variability were calculated. Following 12 weeks of END and HIT, there was no change in heart rate recovery at 1 min (END, 40 ± 12 beats·min(-1) vs. 37 ± 19 beats·min(-1); HIT, 31 ± 8 beats·min(-1) vs. 35 ± 8 beats·min(-1); p ≥ 0.05 for pre- vs. post-training) or 2 min (END, 44 ± 18 beats·min(-1) vs. 43 ± 19 beats·min(-1); HIT, 42 ± 10 beats·min(-1) vs. 50 ± 6 beats·min(-1); p ≥ 0.05 for pre- vs. post-training). All heart rate variability indices were unchanged following END and HIT training. In conclusion, neither END nor HIT exercise programs elicited training-induced improvements in cardiac autonomic function in patients with CAD. The absence of improvements with training may be attributed to the optimal medical management and normative pretraining state of our sample.

  • QRS peak detection for heart rate monitoring on Android smartphone

    NASA Astrophysics Data System (ADS)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  • Smart pillow for heart-rate monitoring using a fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing

    2011-03-01

    In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.

  • Cognitive Performance and Heart Rate Variability: The Influence of Fitness Level

    PubMed Central

    Luque-Casado, Antonio; Zabala, Mikel; Morales, Esther; Mateo-March, Manuel; Sanabria, Daniel

    2013-01-01

    In the present study, we investigated the relation between cognitive performance and heart rate variability as a function of fitness level. We measured the effect of three cognitive tasks (the psychomotor vigilance task, a temporal orienting task, and a duration discrimination task) on the heart rate variability of two groups of participants: a high-fit group and a low-fit group. Two major novel findings emerged from this study. First, the lowest values of heart rate variability were found during performance of the duration discrimination task, compared to the other two tasks. Second, the results showed a decrement in heart rate variability as a function of the time on task, although only in the low-fit group. Moreover, the high-fit group showed overall faster reaction times than the low-fit group in the psychomotor vigilance task, while there were not significant differences in performance between the two groups of participants in the other two cognitive tasks. In sum, our results highlighted the influence of cognitive processing on heart rate variability. Importantly, both behavioral and physiological results suggested that the main benefit obtained as a result of fitness level appeared to be associated with processes involving sustained attention. PMID:23437276

  • Heart rate-left ventricular ejection time relations - Variations during postural change and cardiovascular challenges

    NASA Technical Reports Server (NTRS)

    Lance, V. Q.; Spodick, D. H.

    1976-01-01

    Experiments were conducted on healthy human subjects to determine HR-LVET (Heart Rate-Left Ventricular Ejection Time) regression relations in different postures, including tilt, and during isometric exercise. The subjects were tested in the resting state in supine and sitting positions, during isometric handgrip in supine and sitting positions and during 70 deg headup tilt. The recordings included a bipolar electrocardiogram and a right external carotid pulse curve. Comparison of the HR-LVET relation for the conditions under analysis revealed differences among the respective regression equations, which can be explained by the well-established differences in stroke volume and ejection rate among these states. These differences appear to account for the fact that under conditions in which stroke volume variations should be the major determinant, slopes will be similar but intercepts will vary. Since substantial differences among intercepts are observed, caution should be exercised whenever the intercept factor is used to predict LVET for HR.

  • Effect of energy drink dose on exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise.

    PubMed

    An, Sang Min; Park, Jong Suk; Kim, Sang Ho

    2014-03-01

    The purpose of this research was to investigate the effects of exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise on caffeine concentration of energy drink. The volunteers for this study were 15 male university student. 15 subjects were taken basic physical examinations such as height, weight and BMI before the experiment. Primary tests were examined of VO2max per weight of each subjects by graded exercise test using Bruce protocol. Each of five subject was divided 3 groups (CON, ECGâ…, ECGⅡ) by matched method based on weight and VO2max per weight what gained of primary test for minimize the differences of exercise capacity and ingestion of each groups. For the secondary tests, the groups of subjects were taken their materials before and after exercise as a blind test. After the ingestion, subjects were experimented on exercise test of VO2max 80% by treadmill until the all-out. Heart rate was measured by 1minute interval, and respiratory variables were analyzed VO2, VE, VT, RR and so on by automatic respiratory analyzer. And exercise exhaustion time was determined by stopwatch. Moreover, HRV was measured after exercise and recovery 3 min. Among the intake groups, ECGⅡ was showed the longest of exercise exhaustion time more than CON group (p = .05). Result of heart rate during exercise according to intake groups, there was significant differences of each time (p < .001), however, not significant differences of each groups and group verse time (p > .05). Result of RPE during exercise according to intake groups, there was significant differences of each time (p < .001), however, not significant differences of each groups and group verse time (p > .05). In conclusion, EDGⅡ showed the significant increase of exercise exhaustion time more than CON group (p=.05) and not significant differences in HR, RPE, RER, HRV, HRR, blood pressure (p > .05). Therefore, 2.5 mg/kg(-1) ingestion of energy drink might be positive effect

  • Age-related disappearance of Mayer-like heart rate waves

    NASA Technical Reports Server (NTRS)

    Jarisch, W. R.; Ferguson, J. J.; Shannon, R. P.; Wei, J. Y.; Goldberger, A. L.

    1987-01-01

    The effect of age on the principal spectral components of heart rate obtained immediately after passive upright tilt was investigated in human subjects who underwent a 60-deg tilt over 9 sec. Two groups were examined, the first of which consisting of healthy male subjects aged 22-26 years, while the second was comprised of subjects aged 65-84 years on no medication; radiograms were recorded continuously beginning just prior to tilt until 3 min posttilt. The results of spectral analysis showed that elderly subjects did not exhibit the Mayer-like heart rate waves (the 0.07-0.09 Hz oscillations) that were present in the spectra of young subjects immediately after passive upright tilt. The findings are consistent with the concept of a 'dysautonomia of aging'. It is suggested that postural stress testing with spectral analysis of heart rate fluctuations may provide a useful way of assessing physiologic vs chronologic age.

  • Differing prognostic value of pulse pressure in patients with heart failure with reduced or preserved ejection fraction: results from the MAGGIC individual patient meta-analysis.

    PubMed

    Jackson, Colette E; Castagno, Davide; Maggioni, Aldo P; Køber, Lars; Squire, Iain B; Swedberg, Karl; Andersson, Bert; Richards, A Mark; Bayes-Genis, Antoni; Tribouilloy, Christophe; Dobson, Joanna; Ariti, Cono A; Poppe, Katrina K; Earle, Nikki; Whalley, Gillian; Pocock, Stuart J; Doughty, Robert N; McMurray, John J V

    2015-05-07

    Low pulse pressure is a marker of adverse outcome in patients with heart failure (HF) and reduced ejection fraction (HF-REF) but the prognostic value of pulse pressure in patients with HF and preserved ejection fraction (HF-PEF) is unknown. We examined the prognostic value of pulse pressure in patients with HF-PEF [ejection fraction (EF) ≥ 50%] and HF-REF. Data from 22 HF studies were examined. Preserved left ventricular ejection fraction (LVEF) was defined as LVEF ≥ 50%. All-cause mortality at 3 years was evaluated in 27 046 patients: 22 038 with HF-REF (4980 deaths) and 5008 with HF-PEF (828 deaths). Pulse pressure was analysed in quintiles in a multivariable model adjusted for the previously reported Meta-Analysis Global Group in Chronic Heart Failure prognostic variables. Heart failure and reduced ejection fraction patients in the lowest pulse pressure quintile had the highest crude and adjusted mortality risk (adjusted hazard ratio 1.68, 95% confidence interval 1.53-1.84) compared with all other pulse pressure groups. For patients with HF-PEF, higher pulse pressure was associated with the highest crude mortality, a gradient that was eliminated after adjustment for other prognostic variables. Lower pulse pressure (especially <53 mmHg) was an independent predictor of mortality in patients with HF-REF, particularly in those with an LVEF < 30% and systolic blood pressure <140 mmHg. Overall, this relationship between pulse pressure and outcome was not consistently observed among patients with HF-PEF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  • Dynamic analysis of heart rate may predict subsequent ventricular tachycardia after myocardial infarction

    NASA Technical Reports Server (NTRS)

    Makikallio, T. H.; Seppanen, T.; Airaksinen, K. E.; Koistinen, J.; Tulppo, M. P.; Peng, C. K.; Goldberger, A. L.; Huikuri, H. V.

    1997-01-01

    Dynamics analysis of RR interval behavior and traditional measures of heart rate variability were compared between postinfarction patients with and without vulnerability to ventricular tachyarrhythmias in a case-control study. Short-term fractal correlation of heart rate dynamics was better than traditional measures of heart rate variability in differentiating patients with and without life-threatening arrhythmias.

  • Estimating energy expenditure from heart rate in older adults: a case for calibration.

    PubMed

    Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi

    2014-01-01

    Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.

  • Are Currently Available Wearable Devices for Activity Tracking and Heart Rate Monitoring Accurate, Precise, and Medically Beneficial?

    PubMed Central

    El-Amrawy, Fatema

    2015-01-01

    Objectives The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Methods Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. Results The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. Conclusions The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure. PMID:26618039

  • Are Currently Available Wearable Devices for Activity Tracking and Heart Rate Monitoring Accurate, Precise, and Medically Beneficial?

    PubMed

    El-Amrawy, Fatema; Nounou, Mohamed Ismail

    2015-10-01

    The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure.

  • Comparison of electroacupuncture frequency-related effects on heart rate variability in healthy volunteers: a randomized clinical trial.

    PubMed

    Lee, Jong-Ho; Kim, Kyu-Hyeong; Hong, Jin-Woo; Lee, Won-Chul; Koo, Sungtae

    2011-06-01

    This study aimed to compare the effects of high frequency electroacupuncture (EA) and low-frequency EA on the autonomic nervous system by using a heart rate variability measuring device in normal individuals. Fourteen participants were recruited and each participated in the high-frequency and low-frequency sessions (crossover design). The order of sessions was randomized and the interval between the two sessions was over 2 weeks. Participants received needle insertion with 120-Hz stimulation during the high-frequency session (high-frequency EA group), and with 2-Hz stimulation during the low-frequency session (low-frequency EA group). Acupuncture needles were directly inserted perpendicularly to LI 4 and LI 11 acupoints followed by delivery of electric pulses to these points for 15 minutes. Heart rate variability was measured 5 minutes before and after EA stimulation by a heart rate variability measuring system. We found a significant increase in the standard deviation of the normal-to-normal interval in the high-frequency EA group, with no change in the low-frequency EA group. Both the high-frequency and low-frequency EA groups showed no significant differences in other parameters including high-frequency power, low-frequency power, and the ratio of low-frequency power to high-frequency power. Based on these findings, we concluded that high-frequency EA stimulation is more effective than low-frequency EA stimulation in increasing autonomic nervous activity and there is no difference between the two EA frequencies in enhancing sympathovagal balance. Copyright © 2011 Korean Pharmacopuncture Institute. Published by .. All rights reserved.

  • Prototype early warning system for heart disease detection using Android Application.

    PubMed

    Zennifa, Fadilla; Fitrilina; Kamil, Husnil; Iramina, Keiji

    2014-01-01

    Heart Disease affects approximately 70 million people worldwide where most people do not even know the symptoms. This research examines the prototype of early warning system for heart disease by android application. It aims to facilitate users to early detect heart disease which can be used independently. To build the application in android phone, variable centered intelligence rule system (VCIRS) as decision makers and pulse sensor - Arduino as heart rate detector were applied in this study. Moreover, in Arduino, the heart rate will become an input for symptoms in Android Application. The output of this system is the conclusion statement of users diagnosed with either coronary heart disease, hypertension heart disease, rheumatic heart disease or do not get any kind of heart disease. The result of diagnosis followed by analysis of the value of usage variable rate (VUR) rule usage rate (RUR) and node usage rate (NUR) that shows the value of the rule that will increase when the symptoms frequently appear. This application was compared with the medical analysis from 35 cases of heart disease and it showed concordance between diagnosis from android application and expert diagnosis of the doctors.

  • Gaussian Mixture Model of Heart Rate Variability

    PubMed Central

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  • Blockade of hyperpolarizing currents produces a dose-dependent effect on heart rate.

    PubMed

    Ziyatdinova, N I; Giniatullin, R A; Svyatova, N V; Zefirov, T L

    2001-03-01

    Intravenous injection of ZD 7288, a new specific hyperpolarizing current blocker, dose-dependently reduces heart rate in adult rats. The autonomic nervous system modulates changes in heart rate caused by hyperpolarizing currents.

  • Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders.

    PubMed

    den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu; Brundel, Bianca J J M; Peal, David S; Evans, David M; Nolte, Ilja M; Segrè, Ayellet V; Holm, Hilma; Handsaker, Robert E; Westra, Harm-Jan; Johnson, Toby; Isaacs, Aaron; Yang, Jian; Lundby, Alicia; Zhao, Jing Hua; Kim, Young Jin; Go, Min Jin; Almgren, Peter; Bochud, Murielle; Boucher, Gabrielle; Cornelis, Marilyn C; Gudbjartsson, Daniel; Hadley, David; van der Harst, Pim; Hayward, Caroline; den Heijer, Martin; Igl, Wilmar; Jackson, Anne U; Kutalik, Zoltán; Luan, Jian'an; Kemp, John P; Kristiansson, Kati; Ladenvall, Claes; Lorentzon, Mattias; Montasser, May E; Njajou, Omer T; O'Reilly, Paul F; Padmanabhan, Sandosh; St Pourcain, Beate; Rankinen, Tuomo; Salo, Perttu; Tanaka, Toshiko; Timpson, Nicholas J; Vitart, Veronique; Waite, Lindsay; Wheeler, William; Zhang, Weihua; Draisma, Harmen H M; Feitosa, Mary F; Kerr, Kathleen F; Lind, Penelope A; Mihailov, Evelin; Onland-Moret, N Charlotte; Song, Ci; Weedon, Michael N; Xie, Weijia; Yengo, Loic; Absher, Devin; Albert, Christine M; Alonso, Alvaro; Arking, Dan E; de Bakker, Paul I W; Balkau, Beverley; Barlassina, Cristina; Benaglio, Paola; Bis, Joshua C; Bouatia-Naji, Nabila; Brage, Søren; Chanock, Stephen J; Chines, Peter S; Chung, Mina; Darbar, Dawood; Dina, Christian; Dörr, Marcus; Elliott, Paul; Felix, Stephan B; Fischer, Krista; Fuchsberger, Christian; de Geus, Eco J C; Goyette, Philippe; Gudnason, Vilmundur; Harris, Tamara B; Hartikainen, Anna-Liisa; Havulinna, Aki S; Heckbert, Susan R; Hicks, Andrew A; Hofman, Albert; Holewijn, Suzanne; Hoogstra-Berends, Femke; Hottenga, Jouke-Jan; Jensen, Majken K; Johansson, Asa; Junttila, Juhani; Kääb, Stefan; Kanon, Bart; Ketkar, Shamika; Khaw, Kay-Tee; Knowles, Joshua W; Kooner, Angrad S; Kors, Jan A; Kumari, Meena; Milani, Lili; Laiho, Päivi; Lakatta, Edward G; Langenberg, Claudia; Leusink, Maarten; Liu, Yongmei; Luben, Robert N; Lunetta, Kathryn L; Lynch, Stacey N; Markus, Marcello R P; Marques-Vidal, Pedro; Mateo Leach, Irene; McArdle, Wendy L; McCarroll, Steven A; Medland, Sarah E; Miller, Kathryn A; Montgomery, Grant W; Morrison, Alanna C; Müller-Nurasyid, Martina; Navarro, Pau; Nelis, Mari; O'Connell, Jeffrey R; O'Donnell, Christopher J; Ong, Ken K; Newman, Anne B; Peters, Annette; Polasek, Ozren; Pouta, Anneli; Pramstaller, Peter P; Psaty, Bruce M; Rao, Dabeeru C; Ring, Susan M; Rossin, Elizabeth J; Rudan, Diana; Sanna, Serena; Scott, Robert A; Sehmi, Jaban S; Sharp, Stephen; Shin, Jordan T; Singleton, Andrew B; Smith, Albert V; Soranzo, Nicole; Spector, Tim D; Stewart, Chip; Stringham, Heather M; Tarasov, Kirill V; Uitterlinden, André G; Vandenput, Liesbeth; Hwang, Shih-Jen; Whitfield, John B; Wijmenga, Cisca; Wild, Sarah H; Willemsen, Gonneke; Wilson, James F; Witteman, Jacqueline C M; Wong, Andrew; Wong, Quenna; Jamshidi, Yalda; Zitting, Paavo; Boer, Jolanda M A; Boomsma, Dorret I; Borecki, Ingrid B; van Duijn, Cornelia M; Ekelund, Ulf; Forouhi, Nita G; Froguel, Philippe; Hingorani, Aroon; Ingelsson, Erik; Kivimaki, Mika; Kronmal, Richard A; Kuh, Diana; Lind, Lars; Martin, Nicholas G; Oostra, Ben A; Pedersen, Nancy L; Quertermous, Thomas; Rotter, Jerome I; van der Schouw, Yvonne T; Verschuren, W M Monique; Walker, Mark; Albanes, Demetrius; Arnar, David O; Assimes, Themistocles L; Bandinelli, Stefania; Boehnke, Michael; de Boer, Rudolf A; Bouchard, Claude; Caulfield, W L Mark; Chambers, John C; Curhan, Gary; Cusi, Daniele; Eriksson, Johan; Ferrucci, Luigi; van Gilst, Wiek H; Glorioso, Nicola; de Graaf, Jacqueline; Groop, Leif; Gyllensten, Ulf; Hsueh, Wen-Chi; Hu, Frank B; Huikuri, Heikki V; Hunter, David J; Iribarren, Carlos; Isomaa, Bo; Jarvelin, Marjo-Riitta; Jula, Antti; Kähönen, Mika; Kiemeney, Lambertus A; van der Klauw, Melanie M; Kooner, Jaspal S; Kraft, Peter; Iacoviello, Licia; Lehtimäki, Terho; Lokki, Marja-Liisa L; Mitchell, Braxton D; Navis, Gerjan; Nieminen, Markku S; Ohlsson, Claes; Poulter, Neil R; Qi, Lu; Raitakari, Olli T; Rimm, Eric B; Rioux, John D; Rizzi, Federica; Rudan, Igor; Salomaa, Veikko; Sever, Peter S; Shields, Denis C; Shuldiner, Alan R; Sinisalo, Juha; Stanton, Alice V; Stolk, Ronald P; Strachan, David P; Tardif, Jean-Claude; Thorsteinsdottir, Unnur; Tuomilehto, Jaako; van Veldhuisen, Dirk J; Virtamo, Jarmo; Viikari, Jorma; Vollenweider, Peter; Waeber, Gérard; Widen, Elisabeth; Cho, Yoon Shin; Olsen, Jesper V; Visscher, Peter M; Willer, Cristen; Franke, Lude; Erdmann, Jeanette; Thompson, John R; Pfeufer, Arne; Sotoodehnia, Nona; Newton-Cheh, Christopher; Ellinor, Patrick T; Stricker, Bruno H Ch; Metspalu, Andres; Perola, Markus; Beckmann, Jacques S; Smith, George Davey; Stefansson, Kari; Wareham, Nicholas J; Munroe, Patricia B; Sibon, Ody C M; Milan, David J; Snieder, Harold; Samani, Nilesh J; Loos, Ruth J F

    2013-06-01

    Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously established loci. Experimental downregulation of gene expression in Drosophila melanogaster and Danio rerio identified 20 genes at 11 loci that are relevant for heart rate regulation and highlight a role for genes involved in signal transmission, embryonic cardiac development and the pathophysiology of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate with risk of atrial fibrillation. Our findings provide fresh insights into the mechanisms regulating heart rate and identify new therapeutic targets.

  • Heart rate and heart rate variability response to the transpiration of vortex-water by Begonia Eliator plants to the air in an office during visual display terminal work.

    PubMed

    Johansson, Benny

    2008-10-01

    This study explores the effects of vortex-water transpired from indoor greenery to office air, in relation to heart rate and heart rate variability during exposure to an electromagnetic field (EMF) from a visual display terminal (VDT). The study followed a randomized prospective single group cross-over design. Fifty (50) healthy volunteers, seated in any ordinary working posture in front of a VDT. Electrocardiography was measured in five 10-minute sequential tests. The VDT was turned off during the first test and switched on for the subsequent four tests. During tests 3 and 4, one of two Begonia Eliator plants, irrigated with either tap water or vortex-rotated (active) tap water during growth, was placed adjacent to the VDT. Heart rate, heart rate variability (HRV) and power spectral density (PSD) were analyzed. The heart rate was unchanged at the start of EMF exposure. The time domain measurements indicated a significant decrease in heart rate and a significant increase in HRV, accompanied by higher vagal tone in the presence, and finally in the absence, of the active plant. PSD parameters revealed significantly higher total power, as well as an increase in low frequencies (LF) and high frequencies (HF) in the condition induced by the active plant as well as after its removal. Very low frequencies (VLF) increased at EMF exposure whereas normally HF power decreased, accompanied by a rise in LF power and LF/HF ratio. HF power was higher at exposure to the active compared to the control plant. Spectral power density diagrams revealed an intensified spectral power band at frequencies of around 0.1 Hz at the condition of both plants, indicating systemic autonomic stability. The findings suggest that the parasympathetic response was associated with reduced heart rate, implicating restoration and maintenance of metabolic energy resources mediated by an involuntary adaptation to active plant-related stimuli.

  • Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    PubMed

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  • Heart rate reactivity and current post-traumatic stress disorder when data are missing.

    PubMed

    Jeon-Slaughter, Haekyung; Tucker, Phebe; Pfefferbaum, Betty; North, Carol S; de Andrade, Bernardo Borba; Neas, Barbara

    2011-08-01

    This study demonstrates that auxiliary and exclusion criteria variables increase the effectiveness of missing imputation in correcting underestimation of physiologic reactivity in relation to post-traumatic stress disorder (PTSD) caused by deleting cases with missing physiologic data. This study used data from survivors of the 1995 Oklahoma City bombing and imputed missing heart rate data using auxiliary and exclusion criteria variables. Logistic regression was used to examine heart rate reactivity in relation to current PTSD. Of 113 survivors who participated in the bombing study's 7-year follow-up interview, 42 (37%) had missing data on heart rate reactivity due to exclusion criteria (medical illness or use of cardiovascular or psychotropic medications) or non-participation. Logistic regression results based on imputed heart rate data using exclusion criteria and auxiliary (the presence of any current PTSD arousal symptoms) variables showed that survivors with current bombing-related PTSD had significantly higher heart rates at baseline and recovered more slowly back to baseline heart rate during resting periods than survivors without current PTSD, while results based on complete cases failed to show significant correlations between current PTSD and heart rates at any assessment points. Suggested methods yielded an otherwise undetectable link between physiology and current PTSD. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.

  • heart rate pulse: Topics by Science.gov (2024)
    Top Articles
    Latest Posts
    Recommended Articles
    Article information

    Author: Gov. Deandrea McKenzie

    Last Updated:

    Views: 5945

    Rating: 4.6 / 5 (46 voted)

    Reviews: 85% of readers found this page helpful

    Author information

    Name: Gov. Deandrea McKenzie

    Birthday: 2001-01-17

    Address: Suite 769 2454 Marsha Coves, Debbieton, MS 95002

    Phone: +813077629322

    Job: Real-Estate Executive

    Hobby: Archery, Metal detecting, Kitesurfing, Genealogy, Kitesurfing, Calligraphy, Roller skating

    Introduction: My name is Gov. Deandrea McKenzie, I am a spotless, clean, glamorous, sparkling, adventurous, nice, brainy person who loves writing and wants to share my knowledge and understanding with you.